Mar 21, 2023
Fire pumps, submersible pump applications and anti-clogging of sewage pumps in applications
Fire pumps: Fire pumps are commonly used for firefighting purposes, and work by pumping water into a sprinkler system or a fire hose.Fire pumps are designed to provide water to fire suppression systems, such as sprinklers, standpipes, and fire hydrants. They are usually powered by electric motors, although some are powered by diesel or gasoline engines. The pumps are usually centrifugal pumps and must be designed to meet certain pressure and flow requirements.


Submersible pump applications: Submersible pumps are used in a variety of applications, including sewage, wastewater treatment, industrial water management, and pool and spa applications.Submersible pumps are often used in applications such as sewage, irrigation, and water treatment. The pumps are designed to be submerged in the application's liquid and can be used to transfer, circulate, or lift the liquid. Submersible pumps are often used in applications where the pump needs to be located below the liquid's surface, such as in wells, sewage systems, and irrigation systems.

Anti-clogging of sewage pumps in applications: To prevent clogging of a sewage pump, it is important to ensure that the pump is installed in a location where solids can be collected and removed before they enter the pump. This can be done using a sump pit, a catch basin, or a screened inlet. Additionally, a grinder pump can be used to grind up solids before they enter the pump, preventing clogs and extending the life of the pump.Anti-clogging of sewage pumps is important in applications such as wastewater treatment. This is because sewage pumps can become clogged with solids, which can lead to reduced efficiency, increased wear and tear, and even pump failure. To reduce clogging, the pumps should be designed with features such as large inlet openings, non-clogging impellers, and a large volute area. Additionally, regular maintenance and inspection of the pump should be conducted to ensure that it is operating correctly and is not becoming clogged.
View details
Mar 20, 2023
The critical cavitation allowance of fire pumps and the use of plunger pumps
The critical cavitation allowance (CCA) of fire pumps is the maximum amount of pressure that a pump can withstand before experiencing severe damage due to cavitation. Cavitation occurs when a pump is operating at a pressure that is too high and causes bubbles to form in the liquid being pumped. These bubbles collapse and cause microscopic damage to the pump components.

The critical cavitation allowance of fire pumps is the minimum allowable pressure at which the pump will operate without cavitation. Cavitation is a phenomenon which occurs when the pressure of a liquid drops below its vapor pressure. This can cause damage to the pump components as well as reduce its efficiency. As a result, it is important to ensure the pressure of the liquid is kept above the critical cavitation allowance.

Plunger pumps are commonly used in fire pumps due to their ability to deliver a constant pressure regardless of the flow rate. This makes them ideal for applications where the flow rate can fluctuate. As such, plunger pumps are a good choice for fire pumps as they are able to provide the necessary critical cavitation allowance.

Plunger pumps are commonly used in fire pumps because they are able to withstand higher pressures than other types of pumps. Plunger pumps have a CCA of approximately 150 PSI, which is much higher than other pump types and allows them to be used in higher-pressure applications.

The critical cavitation allowance (CCA) for fire pumps and plunger pumps should be determined by the manufacturer. The CCA is the difference between the inlet pressure and the pressure at which cavitation occurs. It is important for fire pumps and plunger pumps to have sufficient CCA to ensure reliable operation and to prevent damage from cavitation.

Fire pumps require a minimum CCA of 15 psi and a maximum of 25 psi. Plunger pumps require a minimum CCA of 10 psi and a maximum of 40 psi.

The CCA should be determined based on the specific application requirements and the manufacturer’s recommendation. It is important to note that the CCA should never be exceeded as this can lead to cavitation and pump damage.
View details
Mar 20, 2023
The concept of submersible sewage pump and the maintenance points of submersible sewage pump
A submersible sewage pump is a device used to move sewage from a low-lying area such as a septic tank or cesspit to a higher area such as a sewer or drainage system. The pump is typically submerged in the sewage and has a motor for pumping the sewage out of the area.

Maintenance points for submersible sewage pumps:

1. Check the electrical wiring regularly to ensure that the wiring is properly connected and secure.

2. Inspect the pump regularly to ensure that it is in good working condition and that the seals are not worn or damaged.

3. Clean the pump regularly to ensure that it is free of dirt and debris that may affect its performance.

4. Replace the seals and any other parts that may be worn or damaged.

5. Check the motor regularly to ensure that it is in good working condition and that the oil levels are adequate.

6. Test the pump regularly to ensure that it is working properly and that the pressure is adequate.
View details
Mar 17, 2023
Fire pump knowledge and maintenance
Fire pumps are an important part of any commercial or residential fire protection system. Properly functioning fire pumps are essential for providing the necessary water flow and pressure to the fire sprinkler system to help contain and extinguish fires.

Maintenance is key to ensuring the proper and reliable operation of a fire pump. Fire pumps should be inspected and tested at least annually by a qualified professional to ensure they are operating correctly and meeting the necessary requirements. Testing should include a hydrostatic test, a functional test, and a pressure test.

Common maintenance tasks include checking for proper operation of all valves, testing and replacing batteries, lubricating components, and checking and replacing belts and hoses. Additionally, filters and strainers should be checked and cleaned regularly, and all electrical connections should be inspected for corrosion. A qualified professional should also be consulted to ensure the fire pump is in good condition and operating correctly.


A fire pump is a device used to increase the pressure of water supplied to a fire sprinkler system. It is typically powered by an electric motor, and may be driven by a gas engine or diesel engine. Fire pumps are typically installed in commercial and industrial buildings, and are designed to maintain a certain flow rate and pressure in the sprinkler system.

To ensure the fire pump is working properly and providing the necessary pressure, it must be regularly inspected, tested, and maintained. This includes checking the fuel level, lubricating the motor and bearings, inspecting the wiring, testing the pump controller, and ensuring that the pump system is free of any obstructions. The pump should also be tested on a regular basis to ensure it is providing the correct flow rate and pressure. Additionally, the fire pump and its components should be inspected for signs of corrosion or wear, and any necessary repairs should be made.
View details
Mar 17, 2023
Single-stage fire pump characteristics, maintenance and control cabinet requirements
Single-stage fire pump characteristics:

1. A single-stage pump is a basic fire pump that uses a single impeller to draw in and expel water. It is usually used in conjunction with a pressurized water storage tank.

2. A single-stage pump is typically used in residential applications, such as sprinkler systems. It is not suitable for applications that require a high pressure of water, such as large-scale fire suppression systems.

3. Single-stage pumps are generally less expensive than multi-stage pumps, but they are also less efficient and require more energy to run.

Maintenance:

1. To ensure proper operation and performance, single-stage pumps should be inspected and serviced on a regular basis. This includes checking the pump’s impeller, seals, and bearings, as well as examining all electrical connections to ensure they are secure.

2. Regular maintenance also includes testing the pump’s suction and discharge valves, inspecting the motor and motor bearings, and checking the lubrication levels.

3. The pump should also be cleaned on a regular basis to remove any debris or other contaminants that may be present.

Control cabinet requirements:

1. An approved control cabinet must be used to house the fire pump’s control system and other related components.

2. The cabinet must be designed with adequate ventilation to ensure proper operation of the equipment.

3. The cabinet must be constructed of non-combustible materials and must be able to withstand high temperatures.

4. The cabinet must also be equipped with a fire alarm system and a manual override switch to activate the pump in the event of a power failure.
View details
Mar 16, 2023
Preventive measures for common failures of automatic valves and energy-saving working principles of frequency conversion water pumps

1. Preventive measures for common failures of automatic valves:

a) Regularly check and clean the water inlet filter, and replace it regularly.

b) Check the pressure difference of the valve, the working pressure difference should not be too large.

c) Check the seal of the valve, whether the sealing surface is intact.

d) Check whether the actuator has water leakage, if there is water leakage, it needs to be replaced in time.

e) Check whether the electric contact of the valve is normal, and replace the damaged parts in time.

2. Energy-saving working principle of frequency conversion water pump:

The energy-saving working principle of frequency conversion water pump is to adjust the flow rate and pressure of the pump according to the actual needs of the system. When the system needs less water, the frequency converter can adjust the speed of the pump to reduce the flow rate and pressure, so as to achieve the purpose of energy saving. When the system needs more water, the frequency converter can adjust the speed of the pump to increase the flow rate and pressure to meet the needs of the system.

a. The frequency conversion water pump is a variable frequency water pump that can adjust its output power according to the external water pressure and volume. The working principle is to change the frequency of the power supply to change the speed of the motor and the flow rate of the pump.

b. When the water pressure is low, the pump can reduce the speed or output power, thereby saving energy. When the water pressure is high, the pump can increase the speed or output power, so as to meet the water demand.

c. The use of frequency conversion technology can reduce the starting current of the pump, reduce the impact on the power grid, and improve the stability of the power grid.
View details