Follow Us:
Home > Media > News

Fire pump installation, the use of these precautions

Nov 11, 2022
Share:
Fire pump is a more important piece of equipment on the fire fighting system, of course, the correct installation and use of the method is the premise of the normal operation of the fire pump, the following with you, the fire pump of these precautions.

First, the installation of precautions
1. Fire pumps need to be accepted and corrected before installation, and then installed after acceptance, to ensure that the fire pump is accurate for normal operation;
2. Exclude the pipeline should be bracket, the pump is not allowed to bear the load of the pipeline;
3. The location of the installation of the fire pump should be chosen from a spacious area to avoid installation in a narrow area, so that the installation can leave space for future maintenance.

Second, the attention of starting
1、Check the motor steering before starting, see if it is the same direction as the pump steering plate, pan the coupling, the rotation should be light and even, no jamming and stagnation.
2, check the foot bolt is not loose before starting, and lubricating oil and cooling water supply, cooling water for clean soft water, bearing lubrication water pressure flow is not enough, the life of the pump has a serious impact.

Third, the operating precautions
1, during operation, if abnormal noise or vibration is found, should immediately stop, check the cause and troubleshooting;
2, often check the bearing heat, the pump bearing temperature should not exceed 75 ℃, and always check the oil level of the oil cup, regular refueling, if found that the lubricant emulsification phenomenon, should be replaced in a timely manner;
3, often check the motor bearing temperature and stator temperature rise;
4、Frequently check the flow and pressure of the lubricating water of the guide bearing, do not allow the water to be cut off during operation, the lubrication system with filtering device, need to clean the filter regularly;
5, shall not be allowed outside the range allowed in the pump, so as not to overload burned motor;
6, not allowed in the case of insufficient depth under the pump liquid, in order to avoid cavitation damage to the pump;
7, often check the shaft seal leakage and heat, if the leakage is too large, should replace the packing.


Four, close the pump precautions
1、Close the inlet and outlet gate valve and pressure gauge, listen to the cooling and lubricating water of the pump.
2, when to stop the pump operation, gradually close the export gate valve and pressure gauge, and then cut off the power.
3、After the pump has stopped completely, turn off the cooling and lubricating water again.

 There are many other precautions in the installation and use of fire pumps, for more information, please pay attention to the official website of zjbetter.

Inquiry
If you are interested in our products or have some questions, email us, we will contact you as soon as possible.
Name *
Country
Email *
Tel
Flow
Head
Message *
WhatsApp me